Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 133
Filtrar
1.
Acta Chir Belg ; 114(2): 92-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25073205

RESUMO

BACKGROUND: Arterial switch operation became the golden treatment for simple transposition of the great arteries (sTGA). We describe our experience with the arterial switch operation regarding long-term outcome and the need for re-intervention. Nevertheless, supravalvular pulmonary stenosis (SPS) remains a concern in the long run. We assess the evolution of SPS over time and evaluate the effect of technical modifications on SPS during our experience. METHODS: We performed a retrospective study on 133 patients operated with ASO for TGA between October 1991 and November 2009. Last report method was used. We reviewed our pediatric cardiology and cardiac surgery database to examine the echocardiographic data and electrocardiograms. A mean follow-up of 9.2 years (+/- 5.83 SD) was reached. RESULTS: One (0.8%) patient deceased postoperatively due to cardiogenic shock. The overall actuarial freedom from reoperation (open and percutaneous) was 88.1%, 78.5% and 76.9% at 1, 5 and 10 years. SPS needed to be treated in 17 patients. Valve regurgitation at final investigation was maximal moderate in 5 patients for the aortic valve, 10 for pulmonary valve and 3 in tricuspid valve. CONCLUSIONS: ASO shows excellent long-term results in sTGA with a very low morbidity and mortality and is therefore the procedure of choice. Re-intervention rate is determined by SPS. Since the extensive mobilization of the pulmonary arteries and the creation of a longer neo-pulmonary root, reduction in SPS was seen with no re-interventions in the second half of the group. To obtain a final comparison with the atrial switch operation, a longer Follow-up is necessary.


Assuntos
Complicações Pós-Operatórias , Estenose Subvalvar Pulmonar/epidemiologia , Transposição dos Grandes Vasos/cirurgia , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Estenose Subvalvar Pulmonar/diagnóstico , Reoperação , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/mortalidade , Resultado do Tratamento
2.
Thorac Cardiovasc Surg ; 57(5): 257-69, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19629887

RESUMO

OBJECTIVE: The valved bovine conduit "Contegra" for RVOT reconstruction became available for clinical use within a 100 % source data monitored and echo core lab controlled prospective European Multicentre Study, carried out from 1999 to 2006. We present the results of this study. METHODS: A total of 165 Contegras were implanted in 8 centres. The mean patient age was 3.9 years (2 days - 18 years, median 2.0). Total follow-up was 687 patient years. Diagnoses included: tetralogy of Fallot (64 patients, 39 %), truncus arteriosus (50, 30 %), double outlet right ventricle (16, 10 %), aortic valve disease/Ross procedure (11, 7 %), pulmonary valve atresia (10, 6 %), transposition of the great arteries (10, 6 %), 4 other malformations (2 %). Previous procedures were: 82 patients (50 %) - none; 37 (22 %) - valved conduit implantation; 14 (8 %) aortopulmonary shunt; 6 (4 %) catheter intervention. Follow-up appointments which included standardised echocardiography investigations were scheduled at 1, 3, 6, and 12 months, then annually. We evaluated freedom from death, explantation, intervention, stenosis, insufficiency, and degeneration. Results were stratified by age, diagnosis group and conduit size. RESULTS: The 5-year freedom-from rates were: explantation - 90 % (for patients aged 1 to 10 years) and 68 % (for younger patients); endocarditis - over 92 %; catheter intervention - 74 % (patients with congenital malformations); stenosis - 75 % and more (any group); insufficiency - 50 % (12 and 14 mm diameter conduits); any event - 13 % (patients under 1 year), 58 % (1 to 10 years), 82 % (> 10 years). Trace or mild insufficiency was a frequent, but not progressive finding. Mild calcification was detected in only 8 examinations. CONCLUSIONS: The performance of the Contegra conduit compares well with that of homografts when used to reconstruct paediatric right ventricular outflow tracts.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas/cirurgia , Veias Jugulares/transplante , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Animais , Calcinose/etiologia , Calcinose/terapia , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Bovinos , Criança , Pré-Escolar , Endocardite/etiologia , Endocardite/terapia , Europa (Continente) , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/terapia , Cardiopatias Congênitas/mortalidade , Humanos , Lactente , Recém-Nascido , Veias Jugulares/diagnóstico por imagem , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Estudos Prospectivos , Reoperação , Medição de Risco , Fatores de Risco , Fatores de Tempo , Transplante Heterólogo , Resultado do Tratamento , Ultrassonografia , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
3.
Pediatr Cardiol ; 27(5): 633-5, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16944336

RESUMO

A fetus presented with a large pericardial effusion caused by a right atrial transmural tumor. Correct prenatal diagnosis by use of targeted fetal echocardiography indicated that treatment was not required until the gestational age of 36 weeks. At that time, cesarean section was performed because early signs of imminent cardiac tamponade developed ("swinging heart"). At birth, the pericardial effusion was drained with a percutaneous drain. Elective surgical resection was performed on day 6 of life. Histologically, the tumor was a benign capillary hemangioma.


Assuntos
Tamponamento Cardíaco/etiologia , Doenças Fetais , Átrios do Coração , Neoplasias Cardíacas/complicações , Hemangioma/complicações , Adulto , Procedimentos Cirúrgicos Cardíacos , Tamponamento Cardíaco/diagnóstico , Tamponamento Cardíaco/cirurgia , Diagnóstico Diferencial , Ecocardiografia , Feminino , Seguimentos , Neoplasias Cardíacas/diagnóstico , Neoplasias Cardíacas/embriologia , Hemangioma/diagnóstico , Hemangioma/embriologia , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética , Gravidez , Ultrassonografia Pré-Natal
4.
Heart ; 92(11): 1661-6, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16644857

RESUMO

OBJECTIVE: To determine the safety, feasibility and effectiveness of stent expansion of hypoplastic aortic segments with pressure gradients in patients with arterial hypertension. DESIGN: Non-randomised prospective clinical trial. SETTING: Tertiary referral centre, congenital cardiac unit. PATIENT SELECTION: 20 consecutive patients (median age 14.5 years, range 11.6-38.8 years) with arterial hypertension and a hypoplastic segment of the aorta. Seventeen patients had successful previous arch interventions in a coarctation site. INTERVENTIONS: Stent deployment in hypoplastic arch segments. MAIN OUTCOME MEASURES: Gradient across the aortic arch; complications early and during follow up; residual hypertension. RESULTS: 23 stents were deployed: 13 in the cross and 10 in the isthmus. The mean gradient across the aortic arch decreased from 16 (SD 6) (median 17) to 3 (4) (median 1) mm Hg (p < 0.001). In a few patients a mild gradient persisted just distal to the left carotid artery due to residual orificial narrowing or acute angulation. No complications occurred during or after the procedure. During follow up of 2.2 years (range 0.2-4.8 years) arterial hypertension resolved in 10 patients and 10 required residual drug treatment with better control of blood pressures. CONCLUSIONS: Pressure loss due to residual hypoplastic aortic segments can be treated effectively and safely with stent expansion. Some patients remain mildly hypertensive and require additional drug treatment.


Assuntos
Angioplastia com Balão/métodos , Coartação Aórtica/terapia , Hipertensão/terapia , Stents , Adolescente , Adulto , Pressão Sanguínea , Criança , Estudos de Viabilidade , Seguimentos , Humanos , Estudos Prospectivos
5.
Rev Mal Respir ; 22(5 Pt 1): 785-95, 2005 Nov.
Artigo em Francês | MEDLINE | ID: mdl-16272981

RESUMO

UNLABELLED: INTRODUCTION AND STATE OF THE ART: Both short and long-term outcomes following lung transplantation have improved substantially in recent years as a result of advances in the selection and management of donors, organ preservation, immunosuppressive therapy, and the treatment of infectious and malignant complications. In addition surgical techniques have evolved over time and have contributed to this increase in success rates. PERSPECTIVES AND CONCLUSIONS: This review outlines surgical aspects of lung transplantation including a historical note, techniques of lung harvesting, some anaesthetic considerations, the different transplant types and incisions, as well as anastomotic techniques and their pitfalls.


Assuntos
Transplante de Pulmão/métodos , Anestesia/métodos , Ponte Cardiopulmonar , Humanos , Intubação Intratraqueal , Transplante de Pulmão/tendências , Complicações Pós-Operatórias
7.
Heart Surg Forum ; 8(2): E79-81, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15769726

RESUMO

We report a case of a 56-year old man presenting with dehiscence of a valved conduit in the ascending aorta following low-velocity blunt thoracic trauma. The patient had a history of a Bentall procedure in 1994. Two weeks before referral to our hospital, the patient fell during a bicycle ride and hit the handlebars of the bicycle with his chest. During the days following the accident, the patient developed progressively worsening fatigue, shortness of breath, and intolerance for even minor physical effort. The presence of an enlarged ascending aorta surrounding the implanted valved graft was confirmed, and the patient was referred to our department for surgical repair, after which the patient had an uneventful recovery and was discharged home on postoperative day 12.


Assuntos
Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Implante de Prótese de Valva Cardíaca , Deiscência da Ferida Operatória/etiologia , Traumatismos Torácicos/complicações , Ferimentos não Penetrantes/complicações , Acidentes por Quedas , Aorta/diagnóstico por imagem , Aorta/patologia , Ciclismo , Ecocardiografia , Ecocardiografia Transesofagiana , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reoperação , Deiscência da Ferida Operatória/cirurgia , Resultado do Tratamento
8.
Acta Clin Belg ; 60(5): 236-42, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16398320

RESUMO

BACKGROUND: The number of adult patients with surgical repaired congenital heart defects increases continuously. We were interested to compare late outcome after partial and complete atrioventricular defect repair (pAVSD and cAVSD, respectively) and to determine the most important reason for re-intervention. METHODS: All patients older than 16 years, who underwent partial or complete atrioventricular defect repair, were selected from the database. The medical files were reviewed for descriptive statistics. Kaplan Meier analysis was used to determine event free survival for both groups. Log rank testing was performed where applicable. RESULTS: One hundred thirty-eight patients were included. Two patients in each group with early post-operative mortality were excluded (pAVSD: 33/30 male/female, mean age 35.9 +/- 15.6 years; cAVSD: 27/ 44 male/female, mean age 25.7 +/- 11.9 years). Fourteen pAVSD-patients and 23 cAVSD-patients needed a surgical re-intervention: in two and 13 patients, respectively, a mitral valve repair was performed, and in five and one patient, respectively, a mechanical valve was replaced. Eight cAVSD-patients and 10 pAVSD-patients developed atrial arrhythmias. Seven patients (3 cAVSD and 4 pAVSD) received a pacemaker. Median event-free survival time was significantly shorter in the cAVSD-group (22.9 (95% CI 15.4-30.5) years) when compared to the pAVSD-group (34.0 (95% CI 20.1-47.9) years) (Log rank testing, P=0.017). CONCLUSION: Late outcome was characterized by a longer event free follow-up time of pAVSD-patients when compared to cAVSD-patients. The most important reason for re-intervention in both groups was mitral valve regurgitation. However, atrial arrhythmias and conduction disorders were not uncommon late after atrioventricular septal defect repair.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Defeitos dos Septos Cardíacos/cirurgia , Adolescente , Adulto , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Defeitos dos Septos Cardíacos/complicações , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Resultado do Tratamento
9.
Cell Tissue Bank ; 5(4): 253-9, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15591828

RESUMO

Right ventricular outflow tract reconstruction (RVOTR) with cryopreserved allograft for Ross operation and other congenital or acquired cardiac malformation has become a routine and currently, the procedure of choice for children and young patients. A tendency of accelerated degeneration in the youngest recipients has been reported. Some authors advocate the ABO group incompatibility as the main reason for such failure. This retrospective monocentric study presents the long-term outcome of the European Homograft Bank (EHB) cryopreserved allografts, used for RVOTR in Ross operation (group one) and other congenital heart malformation-s (group two). The evaluation of the allograft performance was done by means of echography, considering the allografts with the transvalvular gradient of > or =40 mmHg and/or regurgitation of > or =3+ as failed. Fifty-one patients of group one and 123 of group two were analysed after completed follow-up information. About 25.5% of patients of group one and 30.8% of group two had a compatible, whereas 74.5% of group one and 68.92 of group two an incompatible ABO group with the donor. The mean follow up was 45.77 and 68.88 months, respectively. In second group 22.76% received the aortic, while 77.24% pulmonary allograft. Only three cases of group one (5.88%) failed: one with a compatible (7.69%) and two with an incompatible ABO group (5.26%) (p=0.1), whereas 39 patients (29.4%) of group two failed between 20.1 and 120.2 months (29.73% with and 29.07% without ABO compatibility, p=0.03). Contrary, the age showed more importance in the allograft failure: out of 41 failed allografts, 24 (58.54%) were implanted in patients of 0-5 years (9 or 37.5% with compatible and 15 or 62.5% with incompatible ABO group). Generally, analysing both groups together, there was no influence of ABO mismatching on the allograft failure (p=0.79). Contrary, there was a significant difference in survival between Ross and non-Ross group (p=0.00082).


Assuntos
Sistema ABO de Grupos Sanguíneos , Criopreservação , Rejeição de Enxerto/sangue , Criança , Pré-Escolar , Seguimentos , Valvas Cardíacas , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Fatores de Tempo , Transplante Homólogo , Ultrassonografia
10.
Heart ; 90(9): e56, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15310725

RESUMO

Propionibacterium acnes, a constituent of the human cutaneous flora, infected both the native mitral valve and a Carpentier mitral annuloplasty ring in an adolescent patient. In the case of culture negative endocarditis, the incubation period of blood cultures should be prolonged to identify this pathogen.


Assuntos
Endocardite Bacteriana/microbiologia , Infecções por Bactérias Gram-Positivas , Próteses Valvulares Cardíacas/efeitos adversos , Prolapso da Valva Mitral/cirurgia , Propionibacterium acnes , Infecções Relacionadas à Prótese , Acne Vulgar , Adolescente , Humanos , Masculino
11.
Eur J Cardiothorac Surg ; 25(6): 911-24, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15144988

RESUMO

OBJECTIVES: Quality control is difficult to achieve in Congenital Heart Surgery (CHS) because of the diversity of the procedures. It is particularly needed, considering the potential adverse outcomes associated with complex cases. The aim of this project was to develop a new method based on the complexity of the procedures. METHODS: The Aristotle project, involving a panel of expert surgeons, started in 1999 and included 50 pediatric surgeons from 23 countries, representing the EACTS, STS, ECHSA and CHSS. The complexity was based on the procedures as defined by the STS/EACTS International Nomenclature and was undertaken in two steps: the first step was establishing the Basic Score, which adjusts only the complexity of the procedures. It is based on three factors: the potential for mortality, the potential for morbidity and the anticipated technical difficulty. A questionnaire was completed by the 50 centers. The second step was the development of the Comprehensive Aristotle Score, which further adjusts the complexity according to the specific patient characteristics. It includes two categories of complexity factors, the procedure dependent and independent factors. After considering the relationship between complexity and performance, the Aristotle Committee is proposing that: Performance = Complexity x Outcome. RESULTS: The Aristotle score, allows precise scoring of the complexity for 145 CHS procedures. One interesting notion coming out of this study is that complexity is a constant value for a given patient regardless of the center where he is operated. The Aristotle complexity score was further applied to 26 centers reporting to the EACTS congenital database. A new display of centers is presented based on the comparison of hospital survival to complexity and to our proposed definition of performance. CONCLUSION: A complexity-adjusted method named the Aristotle Score, based on the complexity of the surgical procedures has been developed by an international group of experts. The Aristotle score, electronically available, was introduced in the EACTS and STS databases. A validation process evaluating its predictive value is being developed.


Assuntos
Cardiopatias Congênitas/cirurgia , Garantia da Qualidade dos Cuidados de Saúde/métodos , Procedimentos Cirúrgicos Cardíacos/classificação , Procedimentos Cirúrgicos Cardíacos/normas , Bases de Dados Factuais , Cardiopatias Congênitas/mortalidade , Mortalidade Hospitalar , Humanos , Cooperação Internacional , Pediatria/normas , Controle de Qualidade , Medição de Risco/métodos , Design de Software , Resultado do Tratamento
12.
J Heart Lung Transplant ; 23(1): 105-9, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14734134

RESUMO

BACKGROUND: Phrenic nerve dysfunction (PND) is a well-known complication after cardiac surgery, but reports on its incidence and consequences after heart-lung and lung transplantation are scarce. METHODS: The incidence and consequences (ventilator days and intensive-care unit length of stay [ICU LOS]) of PND were studied by retrospective chart review of 27 heart-lung (HLTx) and 111 lung (LTx) transplantations performed from July 1991 to June 2001 at the Leuven University Hospital, Leuven, Belgium. On clinical suspicion of diaphragmatic dysfunction, nerve conduction studies were performed, which were completed with a needle electromyogram (EMG) of the diaphragm when the conduction study was non-conclusive. RESULTS: The incidence of PND in 21 evaluable HLTx recipients was 42.8% (9 of 21 patients), resulting in significantly more ventilator days for PND patients (37.6 +/- 36.3 days vs 5.3 +/- 3 days; p < 0.05) and a prolonged ICU LOS (46.8 +/- 33 vs 9.8 +/- 4.9 days; p < 0.05). In the 97 evaluable LTx patients, 9.3% (9 of 97 patients) developed PND. This resulted in more ventilator days for the PND group (30.6 +/- 14.8 days vs non-PND 7.9 +/- 14.8 days. p < 0.05) and a longer ICU LOS (PND 37.8 +/- 18.7 days vs non-PND 12.1 +/- 17.8 p < 0.05). Needle EMG of the diaphragm revealed denervation in 1 HLTx and 5 LTx patients. In LTx patients sustaining PND more tracheostomies were performed (44.4% vs 4.5% for non-PND patients p < 0.005). Eight of 9 LTx patients with PND had sequential single-lung transplantation. CONCLUSIONS: PND represents an important clinical problem after HLTx and LTx and has a considerable influence on both number of ventilator days and ICU resource utilization.


Assuntos
Diafragma/inervação , Transplante de Coração-Pulmão , Transplante de Pulmão , Nervo Frênico/fisiopatologia , Complicações Pós-Operatórias/epidemiologia , Adulto , Bélgica/epidemiologia , Diafragma/fisiopatologia , Feminino , Transplante de Coração-Pulmão/estatística & dados numéricos , Humanos , Unidades de Terapia Intensiva , Tempo de Internação , Transplante de Pulmão/estatística & dados numéricos , Masculino , Estudos Retrospectivos
13.
Thorac Cardiovasc Surg ; 51(6): 312-7, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14669126

RESUMO

BACKGROUND: We planned a study to assess the safety, feasibility, and efficacy of the Impella micro-axial blood pump in patients with cardiogenic shock. METHODS: From January 2001 to September 2002 inclusive, 16 patients in cardiogenic shock (maximal inotropic support and with IABP in 11 cases) underwent left ventricle unloading with the Impella pump. 6 were placed via the femoral artery (patients in the coronary care unit) and 10 directly through the aorta (postcardiotomy heart failure). In three patients, the device was used in combination with ECMO. Mean age was 60 years (range 43 - 75), 11 were male. RESULTS: A stable pump flow of 4.24 +/- 0.28 l/min was reached (3.3 +/- 1.9 l/min in patients with ECMO and Impella). Mean blood pressure before Impella) support was 57.4 +/- 13 mmHg, which increased to 74.9 +/- 13 mmHg after 6 hours and 80.6 +/- 17 mmHg (p = 0.003) after 24 hours. Cardiac output increased from 4.1 +/- 1.3 l/min to 5.5 +/- 1.3 (p = 0.003) and 5.9 +/-1.9 l/min (p = 0.01) at 6 and 24 hours. Mean pulmonary wedge pressure decreased from 29 +/- 10 mmHg to 17 +/- 5 mmHg and 18 +/- 7 mmHg at 6 (p = 0.04) and 24 hours. Blood lactate levels decreased significantly after 6 hours of support (from 2.7 +/- 1 to 1.3 +/- 0.5 mmol/l, p = 0.004). Device-related complications included three sensor failures (no clinical action), one pump displacement (replacement) and six incidences of haemolysis (peak free plasma haemoglobin > 100 mg/dl, no clinical action). Eleven patients (68 %) were weaned, six (37 %) survived. CONCLUSIONS: Left ventricular unloading with the Impella pump via the transthoracic or femoral approach is feasible and safe. Support led to a decrease in pulmonary capillary wedge pressure, increase in cardiac output and mean blood pressure, and improved organ perfusion in patients with severe cardiogenic shock.


Assuntos
Coração Auxiliar , Choque Cardiogênico/terapia , Adulto , Idoso , Débito Cardíaco , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Hemoglobinas/análise , Humanos , Masculino , Pessoa de Meia-Idade , Pressão Propulsora Pulmonar , Choque Cardiogênico/fisiopatologia
15.
Ann Thorac Surg ; 71(5 Suppl): S236-9, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11388194

RESUMO

BACKGROUND: This multicenter study concerning the mitral PERIMOUNT valve previously reported clinical results at 12 years; this report updates the performance to 15 years postoperatively. METHODS: The 435 patients (mean age 60.7+/-11.6 years; 41.1% male) underwent implantation with the PERIMOUNT valve between 1984 and 1989 at seven institutions. Follow-up was complete for 96.1% of the cohort. The mean follow-up was 8.1+/-4.4 years (range 0 to 15.4 years) for a total of 3492 patient-years. RESULTS: There were 34 (7.8%) operative deaths, one (0.2%) valve related. The late mortality rate was 5.3%/patient-year (2.2%/patient-year valve related). At 14 years, the overall actuarial survival rate was 37.1%+/-3.3% (63.1%+/-4.4% valve related). Actuarial freedom from complications at 14 years was as follows: thromboembolism, 83.8%+/-3.2% (1.1%/patient-year); hemorrhage, 86.6%+/-3.2% (1.1%/patient-year); and explant due to structural valve deterioration (SVD), 68.8%+/-4.7%. Actual freedom from explant due to SVD was 83.4%+/-2.3%. Rates of structural failure decreased with increasing age at implant. CONCLUSIONS: The Carpentier-Edwards PERIMOUNT Pericardial Bioprosthesis is a reliable choice for a tissue valve in the mitral position, especially in patients more than 60 years of age.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Valva Mitral/cirurgia , Análise Atuarial , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Criança , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Falha de Prótese , Fatores de Risco
16.
Eur Heart J ; 22(12): 1052-9, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11428840

RESUMO

AIMS: This study compares the functional outcome and cardiorespiratory response to exercise, in patients who have undergone arterial switch for transposition of the great arteries, with normal controls and patients who have undergone atrial switch operation. METHODS AND RESULTS: Fifteen patients who had undergone arterial switch (mean age 8.5+/-2.9 years) were compared to 32 patients who had undergone atrial switch (9.2+/-1.8 years) and 27 normal controls (8.5+/-2.1 years). Exercise testing was performed on a treadmill and gas exchange measured breath-by-breath. Aerobic capacity, assessed by determination of the ventilatory anaerobic threshold, averaged 91+/-7.8% of normal (95% confidence limits: 92-108%) for arterial switch and 75.1+/-13.1% for atrial switch (P<0.001 patients vs normals). Aerobic exercise function was evaluated by calculation of the slope of oxygen uptake vs exercise intensity. The mean value for this slope was 2.0+/-0.25 for arterial switch, 2.5+/-0.46 for normals and 1.7+/-0.80 for atrial switch (P<0.05; patients vs normals). Efficiency of the pulmonary gas exchange was assessed by calculation of the slope of ventilation vs carbon dioxide output during exercise. This averaged 38.7+/-14.7 for arterial switch, 48.1+/-14.1 for atrial switch and 30.3+/-7.6 for normals (P<0.001; patients vs normals). CONCLUSION: Cardiorespiratory exercise function is at, or slightly below, the lower limit of normal in patients with arterial switch, while the lowest values were observed for those who had undergone atrial switch.


Assuntos
Frequência Cardíaca , Consumo de Oxigênio , Troca Gasosa Pulmonar , Transposição dos Grandes Vasos/fisiopatologia , Criança , Pré-Escolar , Interpretação Estatística de Dados , Eletrocardiografia , Testes de Função Cardíaca , Humanos , Transposição dos Grandes Vasos/cirurgia
17.
Eur J Cardiothorac Surg ; 19(3): 274-8, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11251265

RESUMO

OBJECTIVES: Aneurysm formation after patch angioplasty for aortic coarctation is a frequent and potentially lethal complication, necessitating surgical reintervention. Although several mechanisms have been postulated, flow disturbance in a concomitant hypoplastic transverse aortic arch most likely contributes to the aneurysm formation. The outcome of the grafts after redo surgery, however, is unknown. The purpose of this study was to evaluate the outcome of the inserted graft in patients with surgery for aneurysm formation following patch angioplasty for coarctation of the aorta. METHODS: In 16 patients redo surgery was performed for aneurysm formation (diameter: 47.1+/-11.9 cm) (mean+/-SD), 12.7+/-2.1 years after the initial patch angioplasty. All patients had a concomitant arch hypoplasia. They were treated by insertion of a Dacron Gelseal graft (16-30 mm), but the associated hypoplastic arch segment was left untouched. To evaluate the evolution of the new graft, patients were followed by means of magnetic resonance (MR) imaging. RESULTS: The immediate postoperative outcome was uneventful in 12 patients. Four patients, however, suffered from a recurrent nerve paralysis and one of them of a spinal cord transection. The mean follow-up time was 54.1+/-17.9 months during which 59 magnetic resonance studies were performed. The number of MR studies per patient ranged from two to seven. The graft diameter increased significantly with 56+/-18%, range 20-82 (P<0.0001). This widening was most pronounced within the first year after surgery (43+/-16%, range 5-67) (P<0.0001). CONCLUSIONS: Flow acceleration caused by an even mild hypoplastic transverse arch can put excessive strain on the distal part of the aortic arch. This can lead not only to aneurysm formation after patch angioplasty but also to excessive dilation of the Dacron Gelseal graft. At intermediate long-term follow-up, however, a stabilization of the graft dilation is observed.


Assuntos
Falso Aneurisma/diagnóstico , Falso Aneurisma/etiologia , Angioplastia/efeitos adversos , Angioplastia/métodos , Coartação Aórtica/cirurgia , Adolescente , Adulto , Falso Aneurisma/mortalidade , Falso Aneurisma/cirurgia , Angioplastia/mortalidade , Coartação Aórtica/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Seguimentos , Rejeição de Enxerto , Sobrevivência de Enxerto , Humanos , Lactente , Angiografia por Ressonância Magnética , Masculino , Probabilidade , Estudos Prospectivos , Radiografia , Reoperação , Taxa de Sobrevida , Resultado do Tratamento
18.
Cardiol Young ; 11(1): 17-24, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11233392

RESUMO

BACKGROUND: At present, a considerable number of patients survive who underwent an atrial switch operation for correction of complete transposition. Our study aimed to assess their long-term exercise performance and the serial evolution of cardiac function. METHODS: We studied 22 patients 5 to 17 years after an atrial switch operation, and followed them serially for 3.5 +/- 2 years after the first evaluation. Cardiorespiratory exercise function was assessed by analysis of gas exhange and by determination of the ventilatory anaerobic threshold. Echocardiography was performed on all evaluations. RESULTS: All patients were in Class I of the classification of the New York Heart Association at all assessments. Ventilatory anaerobic threshold, however, was significantly lower than normal. It averaged 77.9% +/- 13.7 of the normal mean value at the initial evaluation, and remained stable when re-evaluated later (76.2 +/- 13.7%). At the initial study, the increase in oxygen uptake during graded exercise was below the 95% confidence limit in 6 of the patients, and was below this level in 10 patients at re-assessment. The subnormal values for oxygen uptake during submaximal exercise were associated with moderate to severe haemodynamic dysfunction. At echocardiography, 15 of 17 patients studied twice had mild to moderate right ventricular dilation and tricuspidregurgiation, which remained virtually the same at reasssesment. A stable sinus rhythm was initially present in 17 patients, and persisted in 15 patients during follow-up. CONCLUSION: At medium term follow-up, cardiorespiratory exercise performance remains stable in patients after atrial switch repair. Serial exercise testing appears useful, because in individual patients in the present study, a decreasing exercise tolerance correlated with development of haemodynamic sequels.


Assuntos
Frequência Cardíaca , Troca Gasosa Pulmonar , Transposição dos Grandes Vasos/cirurgia , Adolescente , Criança , Pré-Escolar , Ecocardiografia , Teste de Esforço , Feminino , Seguimentos , Humanos , Masculino , Sobreviventes , Transposição dos Grandes Vasos/diagnóstico por imagem , Resultado do Tratamento
19.
Am J Cardiol ; 85(2): 221-5, 2000 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-10955381

RESUMO

Surgical repair of tetralogy of Fallot (TOF) with reconstruction of the right ventricular (RV) outflow tract invariably results in pulmonary regurgitation. Chronic pulmonary regurgitation has been associated with RV dysfunction and decreased exercise performance. The present study assessed the influence of pulmonary valve replacement (PVR) for severe pulmonary regurgitation after previous TOF repair on cardiorespiratory exercise performance and RV function. Eighteen patients, between the ages of 8 and 18 years, underwent an exercise test and a cardiac magnetic resonance imaging scan at least 1 year after PVR. The exercise data were compared with those obtained from 24 age-matched normal controls and 27 age-matched patients with repaired TOF and a moderate degree of pulmonary regurgitation. A subgroup of 11 patients had an exercise test performed before and after PVR. Cardiopulmonary exercise performance was evaluated by determination of the ventilatory anaerobic threshold (VAT) and by the steepness of the slope of oxygen uptake versus exercise intensity (SVO2). After PVR there was a significant increase in VAT (86+/-11% before to 106.9+/-14% after, p = 0.03) and in SVO2 (1.71+/-0.47 to 2.3+/-0.39, p = 0.004). In patients examined after PVR, the VAT and SVO2 values were not significantly different from the values in the normal controls (104+/-15% [p>0.05] and 2.03+/-0.77 after PVR vs. 2.42+/-0.68 [p>0.25], respectively). In contrast, patients with repaired TOF and a moderate degree of pulmonary regurgitation had a significantly lower VAT (86+/-11%, p<0.05) and SVO2 (1.8+/-0.74 vs. 2.42+/-0.68, p<0.05) than normal controls. Magnetic resonance imaging studies revealed residual RV dilatation and dysfunction. However, there was no correlation between RV dilatation and RV dysfunction and aerobic exercise capacity. It is concluded that aerobic exercise capacity substantially improves after PVR for severe pulmonary regurgitation after previous TOF repair. Although the right ventricle remains significantly dilated and hypocontractile, there is no relation between RV function and exercise performance.


Assuntos
Exercício Físico/fisiologia , Complicações Pós-Operatórias/cirurgia , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/transplante , Tetralogia de Fallot/cirurgia , Adolescente , Limiar Anaeróbio , Fenômenos Fisiológicos Cardiovasculares , Criança , Teste de Esforço , Humanos , Imageamento por Ressonância Magnética , Oxigênio/metabolismo , Respiração , Índice de Gravidade de Doença , Função Ventricular , Função Ventricular Direita
20.
J Thorac Cardiovasc Surg ; 120(2): 393-400, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10917959

RESUMO

OBJECTIVE: We sought to identify the indications of mechanical support in postcardiotomy left ventricular failure in patients who are unable to undergo transplantation. METHODS: From 1989 through 1997, 61 patients with postcardiotomy left ventricular failure beyond intra-aortic balloon pumping were assisted with the Hemopump cardiac assist system (Medtronic, Minneapolis, Minn). Their mean age was 64 +/- 8 years. Comorbidity was prevalent; 47% underwent cardiac massage before pump support, and evolving myocardial infarction was diagnosed in 43% before surgery. Multivariable logistic regression of data known at the moment of pump insertion was performed to identify the risk factors for mortality. RESULTS: Sixty-five percent of the patients were weaned from the device, but only 30% were discharged home. Cardiac index evolution during the first hours after pump insertion (P <.001) is the only independent predictor for possibility to wean from the device in the multivariable analysis. Acute renal failure is the only variable retained in the model for 90-day mortality. Device-related complications were far more frequent with the femoral (54%) than with the transthoracic (6%) cannula. Only 13% of the patients had bleeding complications. CONCLUSIONS: One third of the patients with postcardiotomy heart failure refractory to use of the intra-aortic balloon pump can be saved with the use of an endovascular axial flow pump. It is impossible to predict lethal outcome on preoperative data alone. The early hemodynamic response to support seems to be related to functional recovery of the heart and subsequent weaning from the device.


Assuntos
Coração Auxiliar , Hemodinâmica/fisiologia , Complicações Pós-Operatórias/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia , Procedimentos Cirúrgicos Cardíacos , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Análise de Sobrevida , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...